• Skip to main content
  • Skip to secondary menu
  • Skip to primary sidebar
El Blog de Jorge de la Cruz

El Blog de Jorge de la Cruz

El Blog de Jorge de la Cruz - Todas las novedades sobre VMware, Veeam, InfluxData, Grafana, Zimbra, etc.

  • Home
  • VMware
    • VMworld
    • VMware vSphere 6.7
    • VMware vSphere 6.5
  • Veeam
    • Resumen Contenido 2021
    • Veeam v11
      • Continuous Data Protection (CDP
      • Ransomware Protection
      • Archive Tier
      • Mejoras en Instant Recovery
      • Veeam Agent for Mac
      • Veeam Backup for AHV v2.1
    • Veeam Backup for Microsoft Office 365
      • 1 – Razones para proteger nuestra información en Microsoft Office 365
      • 2 – Componentes lógicos de Veeam Backup for Microsoft Office 365 2.0
      • 3 – Instalación paso a paso de Veeam Backup for Microsoft Office 365 v2.0
      • 4 – Configuración inicial de Veeam Backup for Microsoft Office 365 v2.0
      • 5 – Creando trabajos de copia en Veeam Backup for Microsoft Office 365 v2.0
      • 6 – Restaurando elementos en Veeam Backup for Microsoft Office 365 v2.0
    • Veeam Backup for AWS
      • Veeam: Veeam anuncia Veeam Backup for AWS Free Edition
      • Veeam: Cómo Desplegar Veeam Backup for AWS – paso a paso
      • Veeam: Vistazo en profundidad al nuevo Veeam Backup for AWS – Creación de Políticas de Backup y Restauración
      • Veeam: Cómo conectar nuestro Veeam Backup & Replication a Veeam Backup for AWS
    • Veaam ONE
      • En busca del Dashboard perfecto: Veeam ONE – Parte I – Introducción a Veeam ONE
      • En busca del Dashboard perfecto: Veeam ONE – Parte II – Descarga e Instalación de Veeam ONE
      • En busca del Dashboard perfecto: Veeam ONE – Parte III – Añadir una Infraestructura de VMware vSphere a Veeam ONE
      • En busca del Dashboard perfecto: Veeam ONE – Parte IV – Añadir una Infraestructura de Veeam Backup and Replication a Veeam ONE
      • En busca del Dashboard perfecto: Veeam ONE – Parte V – Realizando troubleshooting de vSphere usando Veeam ONE Monitor
      • En busca del Dashboard perfecto: Veeam ONE – Parte VI – Realizando troubleshooting de Veeam Backup and Replication usando Veeam ONE Monitor
      • En busca del Dashboard perfecto: Veeam ONE – Parte VII – Vistazo profundo a los Dashboards en Veeam ONE Reporter
      • En busca del Dashboard perfecto: Veeam ONE – Parte VIII – Vistazo profundo a Reportes en Veeam ONE Reporter
      • En busca del Dashboard perfecto: Veeam ONE – Parte IX – Chargeback para crear reportes de coste de nuestra Infraestructura
    • Veeam Availability Console
      • 1 – Teoría e información útil sobre el producto
      • 2 – Instalación de Veeam Availability Console
      • 3 – Configuración y conexión con VBR Server
      • 4 – Administración centralizada de Veeam Backup Agents
      • 5 – Backup de Agentes a diferentes destinos, SMB, Repositorio Veeam o Cloud Connect
      • 6 – Reportes de Backup de Veeam Agent y Veeam Backup and Replication
      • 7 – Manejando la Facturación de Veeam Agents, Backup and Replication y Cloud Connect
    • Backup y restore de cargas de trabajo a Microsoft Azure
      • 1 – Introducción
      • 2 – Conectividad entre nuestro Datacenter y Microsoft Azure
      • 3 – Desplegar Veeam Backup and Replication en Microsoft Azure
      • 4 – Configuración en nuestro Datacenter para backup a Microsoft Azure
      • 5 – Restaurando a Microsoft Azure, desde Microsoft Azure
      • 6 – Migrar cargas de trabajo desde Microsoft Azure hacía nuestro Datacenter
    • Veeam v9.5 Update 4
      • Veeam Cloud Tier
        • Cómo controlar el ancho de banda en Veeam Cloud Tier
      • Secure Restore y Staged Restore
      • Mejoras en Veeam Agent Management
      • Veeam Community Edition
      • Actualizar Veeam Enterprise Manager y Veeam Backup and Replication a la última versión
      • VeeamONE con Intelligent Diagnostics, Remediation actions, Business View 2.0 y Application Monitoring
    • VeeamON 2022
      • Novedades en Veeam ONE v12
    • VeeamON 2021
      • VBO v6 – Self-Service y Backup Copy Glacier-Azure Archive
    • VeeamON 2020
      • Veeam Backup for AWS v2.0
    • VeeamON 2019
      • Veeam Availability Orchestrator v2.0 – ¡novedades!
    • VeeamON 2017
      • Sesiones recomendadas
      • Día I – Veeam Availability Suite v10 – ¡novedades!
      • Día II – Veeam Azure PN (Powered Network), Scale-out Archive Tier y mucho más
    • VeeamON 2015
      • VeeamON 2015 volverá a Las Vegas en el único Evento sobre Disponibilidad en el Data Center
      • Completo resumen, keynotes e imágenes
      • vBrownBag – Jorge de la Cruz – Stop sending postcards to your customers
  • Zextras
  • PRTG
  • Office 365
    • Microsoft – Añadiendo nuestro dominio a Office 365, configuración de DNS y migración de actual Mailbox
    • Veeam: Usando Microsoft Office 365 para nuestras notificaciones por correo electrónico
    • PRTG: Usando Microsoft Office 365 para nuestras notificaciones por correo electrónico
  • Zimbra
    • Instalación
      • Instalando Zimbra 8.7.6 sobre Ubuntu 14.04 LTS – ¡con Chat y Drive!
      • Amazon Lightsail para instalar Zimbra Collaboration 8.7.1, Parte II
      • Amazon Lightsail para instalar Zimbra Collaboration 8.7.1, Parte I
      • Instalando Zimbra 8.7.x con un solo comando, incluye Chat y Drive
  • Linux
    • InfluxDB, Grafana y Telegraf
      • 1 – Instalación y configuración de los components
      • 2 – Instalar agente en Linux
      • 3 – Integración con PRTG
      • 4 – Instalar agente Telegraf en Nodos remotos Windows
      • 5 – Activar inputs específicos, Red, MySQL/MariaDB, Nginx
      • 6 – Monitorizando Veeam
    • Ansible y Zabbix
      • 1 – Inicio
      • 2 – Instalación de Ansible e integración con Active Directory
      • 3 – Configuración de AutoDiscovery en Zabbix
      • 4 – Instalación del agente de Zabbix en Windows
      • 5 – Instalación del agente de Zabbix en Linux y Auto Remove en Zabbix
    • Jenkins
      • 1 – Inicio
      • 2 – Instalación de Jenkins en Ubuntu
      • 3 – Instalando nuestro primer plugin
      • 4 – Sincronización NTP de Linux
      • 5 – Añadir un Slave Windows a Jenkins
      • 6 – Ejecutar tareas en Linux
      • 7 – Ejecutar tareas en Windows
    • Kubernetes
      • 1 – Introducción a Kubernetes
      • 2 – Instalación paso a paso
      • 3 – RollingUpdate con Kubernetes
      • 4 – Dashboard
      • 5 – Volúmenes NFS
      • 6 – Registry
      • 7 – Traefik
      • 8 – Systemd con Traefik y Proxy de Kubernetes
      • 9 – Heapster Influx Grafana
      • 10 – Labels de Kubernetes
      • 11 – API: Swagger
      • 12 – API: Creando nuestro primer POD
  • Contribuidores
    • Acerca de Jorge
    • Acerca de Oscar Mas
      • Clúster SQL
        • 1 – Introducción
        • 2 – Preparación de los equipos virtuales
        • 3 – Instalación del Clúster de Microsoft
        • 4 – Instalación de SQL Server para Clúster de Microsoft
        • 5 – Configuración de nuestro Clúster de SQL
        • 6 – Monitorización de Clúster de SQL con Zabbix
        • 7 – Actualizando clúster de SQL

VMware: VMware anuncia ESXi 6.5 Update 1 Patch 2, actualizar paso a paso con online depot (no ISO)

29 December, 2017 - Escrito en: vmware

Saludos amigos, antes de terminar el año, VMware ha anunciado un Patch 2 para nuestro ESXi 6.5 Update 1. En concreto estoy hablando de los siguientes números de builds:

Nombre Patch Fecha Build
ESXi 6.5 Patch 2* ESXi650-201712001 19-12-2017 7388607
ESXi 6.5 Patch 2* (Security only) ESXi650-201712001 19-12-2017 7273056

El paquete entero que pesa 478.5 MB y que lleva el nombre de ESXi650-201712001.zip, lo podemos descargar desde la web de VMware como siempre aquí.

Este paquete es realmente interesante e incluye dos parches de seguridad crítica, y otros tantos importantes, por lo tanto os recomiendo tenerlo instalado, siempre.

Proceso de actualización de ESXi usando online bundle (no ISO)

Lo primero que podemos comprobar es la versión en la que nos encontramos, en mi caso me encuentro en ESXi 6.5 Update 1, lanzada el 27 de Julio de 2017:

Migrar o apagar las VM del Host

Una de las grandes ventajas que tiene VMware, es que podemos migrar las VM en caliente ante intervenciones como esta, es tan sencillo como irnos al Host que queremos actualizar – VM, y hacer click derecho en una o varias, y click en Migrate y posteriormente le diremos Change HostUna vez tenemos las VM apagadas, o correctamente migradas de Host, comprobaremos que en el Host tenemos el Firewall habilitado para el puerto 22:Y que en Services, tenemos el servicio de SSH iniciado, también podemos cambiar la política para que se arranque automáticamente siempre:

Poner el Host en modo Mantenimiento

Cuando hemos realizado todos estos pasos, ya podemos poner el Host en Modo Mantenimiento:

Desde aquí podríamos decir que queremos mover las VM apagadas a otro host, pero lo he desmarcado ya que no es necesario:

Comprobar el offline depot y ejecutarlo

Es la hora de conectarnos mediante SSH al Host de ESXi y lanzar los siguientes comandos.

Comenzaremos habilitando el firewall para que se pueda conectar por http a servidores externos, es posible que no os haga falta, pero por si acaso:

esxcli network firewall ruleset set -e true -r httpClient

Ahora descargaremos la imagen del Patch2 desde la web de VMware directamente, que además nos advertirá de los paquetes VIB que eliminará, este proceso puede tardar un poco más o menos dependiendo de vuestro ancho de banda:

 esxcli software profile install -p ESXi-6.5.0-20171204001-standard -d https://hostupdate.vmware.com/software/VUM/PRODUCTION/main/vmw-depot-index.xml

En mi caso me avisa de lo siguiente, al ser una imagen personalizada de HP, muchos de los drivers personalizados que trae serán eliminados, por lo que os recomiendo ponderar si os interesa o no descargar este patch y luego volver a cargar todos estos VIB:

 [Exception]
 You attempted to install an image profile which would have resulted in the removal of VIBs ['HPE_bootbank_hpe-ilo_650.10.0.1-24.4240417', 'HPE_bootbank_hponcfg_6.0.0.4.4-2.4.2494585', 'HPE_bootbank_hpe-cru_650.6.5.8.24-1.4240417', 'HPE_bootbank_hpe-build_650.9.6.0.28-4240417', 'HPE_bootbank_hpe-esxi-fc-enablement_650.2.6.10-4240417', 'HPE_bootbank_ssacli_2.60.18.0-6.0.0.2494585', 'ELX_bootbank_elx-esx-libelxima.so_11.1.216.0-03', 'HPE_bootbank_conrep_6.0.0.01-02.00.1.2494585', 'HPE_bootbank_hpe-smx-provider_650.03.11.00.17-4240417', 'HPE_bootbank_amshelper_650.10.6.0-24.4240417', 'HPE_bootbank_scsi-hpdsa_5.5.0.54-1OEM.550.0.0.1331820', 'HPE_bootbank_hptestevent_6.0.0.01-01.00.5.2494585', 'EMU_bootbank_elxiscsi_11.1.216.0-1OEM.650.0.0.4240417', 'HPE_bootbank_hpbootcfg_6.0.0.02-02.00.6.2494585', 'HPE_bootbank_scsi-hpvsa_5.5.0.102-1OEM.550.0.0.1331820', 'HPE_bootbank_hpe-nmi_600.2.4.16-2494575']. If this is not what you intended, you may use the esxcli software profile update command to preserve the VIBs above. If this is what you intended, please use the --ok-to-remove option to explicitly allow the removal.
 Please refer to the log file for more details.

En mi Supermicro el mensaje es menos radical respecto a paquetes a eliminar:

esxcli software profile install -p ESXi-6.5.0-20171204001-standard -d https://hostupdate.vmware.com/software/VUM/PRODUCTION/main/vmw-depot-index.xml
 [Exception]
 You attempted to install an image profile which would have resulted in the removal of VIBs ['VMware_bootbank_vmware-fdm_6.5.0-6816762']. If this is not what you intended, you may use the esxcli software profile update command to preserve the VIBs above. If this is what you intended, please use the --ok-to-remove option to explicitly allow the removal.
 Please refer to the log file for more details.

Yo he dicho que si con el siguiente comando, además otros Hosts de otras marcas seguramente solamente os den conflicto uno o dos paquetes o ninguno, lanzaremos el mismo comando pero con –ok-to-remove al final:

esxcli software profile install -p ESXi-6.5.0-20171204001-standard -d https://hostupdate.vmware.com/software/VUM/PRODUCTION/main/vmw-depot-index.xml --ok-to-remove

Pasados unos minutos podremos comprobar el resultado satisfactorio de instalación, con todos los paquetes que se han eliminado, instalado o skipped:

En mi HP MicroServer

Installation Result
   Message: The update completed successfully, but the system needs to be rebooted for the changes to be effective.
   Reboot Required: true
   VIBs Installed: VMW_bootbank_elxnet_11.1.91.0-1vmw.650.0.0.4564106, VMW_bootbank_igbn_0.1.0.0-15vmw.650.1.36.7388607, VMW_bootbank_lpfc_11.1.0.6-1vmw.650.0.0.4564106, VMW_bootbank_misc-cnic-register_1.78.75.v60.7-1vmw.650.0.0.4564106, VMW_bootbank_misc-drivers_6.5.0-1.36.7388607, VMW_bootbank_net-bnx2_2.2.4f.v60.10-2vmw.650.0.0.4564106, VMW_bootbank_net-bnx2x_1.78.80.v60.12-1vmw.650.0.0.4564106, VMW_bootbank_net-cnic_1.78.76.v60.13-2vmw.650.0.0.4564106, VMW_bootbank_nhpsa_2.0.6-3vmw.650.0.0.4564106, VMW_bootbank_ntg3_4.1.3.0-1vmw.650.1.36.7388607, VMW_bootbank_nvme_1.2.0.32-5vmw.650.1.36.7388607, VMW_bootbank_nvmxnet3_2.0.0.23-1vmw.650.1.36.7388607, VMW_bootbank_qedentv_2.0.3.29-1vmw.650.0.0.4564106, VMW_bootbank_qfle3_1.0.2.7-1vmw.650.0.0.4564106, VMW_bootbank_scsi-bnx2fc_1.78.78.v60.8-1vmw.650.0.0.4564106, VMW_bootbank_scsi-bnx2i_2.78.76.v60.8-1vmw.650.0.0.4564106, VMW_bootbank_vmkata_0.1-1vmw.650.1.36.7388607, VMW_bootbank_vmkusb_0.1-1vmw.650.1.36.7388607, VMware_bootbank_esx-base_6.5.0-1.36.7388607, VMware_bootbank_esx-dvfilter-generic-fastpath_6.5.0-1.36.7388607, VMware_bootbank_esx-tboot_6.5.0-1.36.7388607, VMware_bootbank_esx-ui_1.23.0-6506686, VMware_bootbank_vsan_6.5.0-1.36.7388608, VMware_bootbank_vsanhealth_6.5.0-1.36.7388609
   VIBs Removed: ELX_bootbank_elx-esx-libelxima.so_11.1.216.0-03, EMU_bootbank_elxiscsi_11.1.216.0-1OEM.650.0.0.4240417, EMU_bootbank_elxnet_11.1.196.3-1OEM.650.0.0.4240417, EMU_bootbank_lpfc_11.1.196.3-1OEM.650.0.0.4240417, HPE_bootbank_amshelper_650.10.6.0-24.4240417, HPE_bootbank_conrep_6.0.0.01-02.00.1.2494585, HPE_bootbank_hpbootcfg_6.0.0.02-02.00.6.2494585, HPE_bootbank_hpe-build_650.9.6.0.28-4240417, HPE_bootbank_hpe-cru_650.6.5.8.24-1.4240417, HPE_bootbank_hpe-esxi-fc-enablement_650.2.6.10-4240417, HPE_bootbank_hpe-ilo_650.10.0.1-24.4240417, HPE_bootbank_hpe-nmi_600.2.4.16-2494575, HPE_bootbank_hpe-smx-provider_650.03.11.00.17-4240417, HPE_bootbank_hponcfg_6.0.0.4.4-2.4.2494585, HPE_bootbank_hptestevent_6.0.0.01-01.00.5.2494585, HPE_bootbank_scsi-hpdsa_5.5.0.54-1OEM.550.0.0.1331820, HPE_bootbank_scsi-hpvsa_5.5.0.102-1OEM.550.0.0.1331820, HPE_bootbank_ssacli_2.60.18.0-6.0.0.2494585, Microsemi_bootbank_nhpsa_2.0.10-1OEM.650.0.0.4240417, QLC_bootbank_qedentv_3.0.4.13-1OEM.650.0.0.4240417, QLC_bootbank_qfle3_1.0.28.0-1OEM.650.0.0.4240417, QLogic_bootbank_misc-cnic-register_1.713.10.v60.1-1OEM.600.0.0.2494585, QLogic_bootbank_net-bnx2_2.2.6a.v60.4-1OEM.600.0.0.2494585, QLogic_bootbank_net-bnx2x_2.713.10.v60.4-1OEM.600.0.0.2494585, QLogic_bootbank_net-cnic_2.713.20.v60.5-1OEM.600.0.0.2494585, QLogic_bootbank_scsi-bnx2fc_1.713.20.v60.4-1OEM.600.0.0.2494585, QLogic_bootbank_scsi-bnx2i_2.713.10.v60.3-1OEM.600.0.0.2494585, VMW_bootbank_igbn_0.1.0.0-14vmw.650.1.26.5969303, VMW_bootbank_misc-drivers_6.5.0-1.26.5969303, VMW_bootbank_ntg3_4.1.2.0-1vmw.650.1.26.5969303, VMW_bootbank_nvme_1.2.0.32-4vmw.650.1.26.5969303, VMW_bootbank_nvmxnet3_2.0.0.22-1vmw.650.0.0.4564106, VMW_bootbank_vmkata_0.1-1vmw.650.1.26.5969303, VMW_bootbank_vmkusb_0.1-1vmw.650.1.26.5969303, VMware_bootbank_esx-base_6.5.0-1.26.5969303, VMware_bootbank_esx-dvfilter-generic-fastpath_6.5.0-0.0.4564106, VMware_bootbank_esx-tboot_6.5.0-1.26.5969303, VMware_bootbank_esx-ui_1.21.0-5724747, VMware_bootbank_vsan_6.5.0-1.26.5912915, VMware_bootbank_vsanhealth_6.5.0-1.26.5912974
   VIBs Skipped: VMW_bootbank_ata-libata-92_3.00.9.2-16vmw.650.0.0.4564106, VMW_bootbank_ata-pata-amd_0.3.10-3vmw.650.0.0.4564106, VMW_bootbank_ata-pata-atiixp_0.4.6-4vmw.650.0.0.4564106, VMW_bootbank_ata-pata-cmd64x_0.2.5-3vmw.650.0.0.4564106, VMW_bootbank_ata-pata-hpt3x2n_0.3.4-3vmw.650.0.0.4564106, VMW_bootbank_ata-pata-pdc2027x_1.0-3vmw.650.0.0.4564106, VMW_bootbank_ata-pata-serverworks_0.4.3-3vmw.650.0.0.4564106, VMW_bootbank_ata-pata-sil680_0.4.8-3vmw.650.0.0.4564106, VMW_bootbank_ata-pata-via_0.3.3-2vmw.650.0.0.4564106, VMW_bootbank_block-cciss_3.6.14-10vmw.650.0.0.4564106, VMW_bootbank_char-random_1.0-3vmw.650.0.0.4564106, VMW_bootbank_ehci-ehci-hcd_1.0-4vmw.650.0.14.5146846, VMW_bootbank_hid-hid_1.0-3vmw.650.0.0.4564106, VMW_bootbank_i40en_1.3.1-5vmw.650.1.26.5969303, VMW_bootbank_ima-qla4xxx_2.02.18-1vmw.650.0.0.4564106, VMW_bootbank_ipmi-ipmi-devintf_39.1-4vmw.650.0.0.4564106, VMW_bootbank_ipmi-ipmi-msghandler_39.1-4vmw.650.0.0.4564106, VMW_bootbank_ipmi-ipmi-si-drv_39.1-4vmw.650.0.0.4564106, VMW_bootbank_ixgben_1.4.1-2vmw.650.1.26.5969303, VMW_bootbank_lsi-mr3_6.910.18.00-1vmw.650.0.0.4564106, VMW_bootbank_lsi-msgpt2_20.00.01.00-3vmw.650.0.0.4564106, VMW_bootbank_lsi-msgpt3_12.00.02.00-11vmw.650.0.0.4564106, VMW_bootbank_mtip32xx-native_3.9.5-1vmw.650.0.0.4564106, VMW_bootbank_ne1000_0.8.0-16vmw.650.1.26.5969303, VMW_bootbank_nenic_1.0.0.2-1vmw.650.0.0.4564106, VMW_bootbank_net-cdc-ether_1.0-3vmw.650.0.0.4564106, VMW_bootbank_net-e1000_8.0.3.1-5vmw.650.0.0.4564106, VMW_bootbank_net-e1000e_3.2.2.1-2vmw.650.0.0.4564106, VMW_bootbank_net-enic_2.1.2.38-2vmw.650.0.0.4564106, VMW_bootbank_net-fcoe_1.0.29.9.3-7vmw.650.0.0.4564106, VMW_bootbank_net-forcedeth_0.61-2vmw.650.0.0.4564106, VMW_bootbank_net-igb_5.0.5.1.1-5vmw.650.0.0.4564106, VMW_bootbank_net-ixgbe_3.7.13.7.14iov-20vmw.650.0.0.4564106, VMW_bootbank_net-libfcoe-92_1.0.24.9.4-8vmw.650.0.0.4564106, VMW_bootbank_net-mlx4-core_1.9.7.0-1vmw.650.0.0.4564106, VMW_bootbank_net-mlx4-en_1.9.7.0-1vmw.650.0.0.4564106, VMW_bootbank_net-nx-nic_5.0.621-5vmw.650.0.0.4564106, VMW_bootbank_net-tg3_3.131d.v60.4-2vmw.650.0.0.4564106, VMW_bootbank_net-usbnet_1.0-3vmw.650.0.0.4564106, VMW_bootbank_net-vmxnet3_1.1.3.0-3vmw.650.0.0.4564106, VMW_bootbank_nmlx4-core_3.16.0.0-1vmw.650.0.0.4564106, VMW_bootbank_nmlx4-en_3.16.0.0-1vmw.650.0.0.4564106, VMW_bootbank_nmlx4-rdma_3.16.0.0-1vmw.650.0.0.4564106, VMW_bootbank_nmlx5-core_4.16.0.0-1vmw.650.0.0.4564106, VMW_bootbank_ohci-usb-ohci_1.0-3vmw.650.0.0.4564106, VMW_bootbank_pvscsi_0.1-1vmw.650.1.26.5969303, VMW_bootbank_qflge_1.1.0.3-1vmw.650.0.0.4564106, VMW_bootbank_qlnativefc_2.1.50.0-1vmw.650.1.26.5969303, VMW_bootbank_sata-ahci_3.0-26vmw.650.1.26.5969303, VMW_bootbank_sata-ata-piix_2.12-10vmw.650.0.0.4564106, VMW_bootbank_sata-sata-nv_3.5-4vmw.650.0.0.4564106, VMW_bootbank_sata-sata-promise_2.12-3vmw.650.0.0.4564106, VMW_bootbank_sata-sata-sil24_1.1-1vmw.650.0.0.4564106, VMW_bootbank_sata-sata-sil_2.3-4vmw.650.0.0.4564106, VMW_bootbank_sata-sata-svw_2.3-3vmw.650.0.0.4564106, VMW_bootbank_scsi-aacraid_1.1.5.1-9vmw.650.0.0.4564106, VMW_bootbank_scsi-adp94xx_1.0.8.12-6vmw.650.0.0.4564106, VMW_bootbank_scsi-aic79xx_3.1-5vmw.650.0.0.4564106, VMW_bootbank_scsi-fnic_1.5.0.45-3vmw.650.0.0.4564106, VMW_bootbank_scsi-hpsa_6.0.0.84-1vmw.650.0.0.4564106, VMW_bootbank_scsi-ips_7.12.05-4vmw.650.0.0.4564106, VMW_bootbank_scsi-iscsi-linux-92_1.0.0.2-3vmw.650.0.0.4564106, VMW_bootbank_scsi-libfc-92_1.0.40.9.3-5vmw.650.0.0.4564106, VMW_bootbank_scsi-megaraid-mbox_2.20.5.1-6vmw.650.0.0.4564106, VMW_bootbank_scsi-megaraid-sas_6.603.55.00-2vmw.650.0.0.4564106, VMW_bootbank_scsi-megaraid2_2.00.4-9vmw.650.0.0.4564106, VMW_bootbank_scsi-mpt2sas_19.00.00.00-1vmw.650.0.0.4564106, VMW_bootbank_scsi-mptsas_4.23.01.00-10vmw.650.0.0.4564106, VMW_bootbank_scsi-mptspi_4.23.01.00-10vmw.650.0.0.4564106, VMW_bootbank_scsi-qla4xxx_5.01.03.2-7vmw.650.0.0.4564106, VMW_bootbank_shim-iscsi-linux-9-2-1-0_6.5.0-0.0.4564106, VMW_bootbank_shim-iscsi-linux-9-2-2-0_6.5.0-0.0.4564106, VMW_bootbank_shim-libata-9-2-1-0_6.5.0-0.0.4564106, VMW_bootbank_shim-libata-9-2-2-0_6.5.0-0.0.4564106, VMW_bootbank_shim-libfc-9-2-1-0_6.5.0-0.0.4564106, VMW_bootbank_shim-libfc-9-2-2-0_6.5.0-0.0.4564106, VMW_bootbank_shim-libfcoe-9-2-1-0_6.5.0-0.0.4564106, VMW_bootbank_shim-libfcoe-9-2-2-0_6.5.0-0.0.4564106, VMW_bootbank_shim-vmklinux-9-2-1-0_6.5.0-0.0.4564106, VMW_bootbank_shim-vmklinux-9-2-2-0_6.5.0-0.0.4564106, VMW_bootbank_shim-vmklinux-9-2-3-0_6.5.0-0.0.4564106, VMW_bootbank_uhci-usb-uhci_1.0-3vmw.650.0.0.4564106, VMW_bootbank_usb-storage-usb-storage_1.0-3vmw.650.0.0.4564106, VMW_bootbank_usbcore-usb_1.0-3vmw.650.1.26.5969303, VMW_bootbank_vmkplexer-vmkplexer_6.5.0-0.0.4564106, VMW_bootbank_vmw-ahci_1.0.0-39vmw.650.1.26.5969303, VMW_bootbank_xhci-xhci_1.0-3vmw.650.0.0.4564106, VMware_bootbank_cpu-microcode_6.5.0-0.0.4564106, VMware_bootbank_emulex-esx-elxnetcli_11.1.28.0-0.0.4564106, VMware_bootbank_esx-xserver_6.5.0-0.23.5969300, VMware_bootbank_lsu-hp-hpsa-plugin_2.0.0-5vmw.650.1.26.5969303, VMware_bootbank_lsu-lsi-lsi-mr3-plugin_1.0.0-10vmw.650.1.26.5969303, VMware_bootbank_lsu-lsi-lsi-msgpt3-plugin_1.0.0-7vmw.650.1.26.5969303, VMware_bootbank_lsu-lsi-megaraid-sas-plugin_1.0.0-8vmw.650.1.26.5969303, VMware_bootbank_lsu-lsi-mpt2sas-plugin_2.0.0-6vmw.650.1.26.5969303, VMware_bootbank_native-misc-drivers_6.5.0-0.0.4564106, VMware_bootbank_rste_2.0.2.0088-4vmw.650.0.0.4564106, VMware_bootbank_vmware-esx-esxcli-nvme-plugin_1.2.0.10-1.26.5969303, VMware_locker_tools-light_6.5.0-1.33.7273056

En mi Supermicro

Installation Result
   Message: The update completed successfully, but the system needs to be rebooted for the changes to be effective.
   Reboot Required: true
   VIBs Installed: VMW_bootbank_igbn_0.1.0.0-15vmw.650.1.36.7388607, VMW_bootbank_misc-drivers_6.5.0-1.36.7388607, VMW_bootbank_ntg3_4.1.3.0-1vmw.650.1.36.7388607, VMW_bootbank_nvme_1.2.0.32-5vmw.650.1.36.7388607, VMW_bootbank_nvmxnet3_2.0.0.23-1vmw.650.1.36.7388607, VMW_bootbank_vmkata_0.1-1vmw.650.1.36.7388607, VMW_bootbank_vmkusb_0.1-1vmw.650.1.36.7388607, VMware_bootbank_esx-base_6.5.0-1.36.7388607, VMware_bootbank_esx-dvfilter-generic-fastpath_6.5.0-1.36.7388607, VMware_bootbank_esx-tboot_6.5.0-1.36.7388607, VMware_bootbank_esx-ui_1.23.0-6506686, VMware_bootbank_vsan_6.5.0-1.36.7388608, VMware_bootbank_vsanhealth_6.5.0-1.36.7388609, VMware_locker_tools-light_6.5.0-1.33.7273056
   VIBs Removed: VMW_bootbank_igbn_0.1.0.0-14vmw.650.1.26.5969303, VMW_bootbank_misc-drivers_6.5.0-1.26.5969303, VMW_bootbank_ntg3_4.1.2.0-1vmw.650.1.26.5969303, VMW_bootbank_nvme_1.2.0.32-4vmw.650.1.26.5969303, VMW_bootbank_nvmxnet3_2.0.0.22-1vmw.650.0.0.4564106, VMW_bootbank_vmkata_0.1-1vmw.650.1.26.5969303, VMW_bootbank_vmkusb_0.1-1vmw.650.1.26.5969303, VMware_bootbank_esx-base_6.5.0-1.26.5969303, VMware_bootbank_esx-dvfilter-generic-fastpath_6.5.0-0.0.4564106, VMware_bootbank_esx-tboot_6.5.0-1.26.5969303, VMware_bootbank_esx-ui_1.24.0-7119706, VMware_bootbank_vmware-fdm_6.5.0-6816762, VMware_bootbank_vsan_6.5.0-1.26.5912915, VMware_bootbank_vsanhealth_6.5.0-1.26.5912974, VMware_locker_tools-light_6.5.0-0.23.5969300
   VIBs Skipped: VMW_bootbank_ata-libata-92_3.00.9.2-16vmw.650.0.0.4564106, VMW_bootbank_ata-pata-amd_0.3.10-3vmw.650.0.0.4564106, VMW_bootbank_ata-pata-atiixp_0.4.6-4vmw.650.0.0.4564106, VMW_bootbank_ata-pata-cmd64x_0.2.5-3vmw.650.0.0.4564106, VMW_bootbank_ata-pata-hpt3x2n_0.3.4-3vmw.650.0.0.4564106, VMW_bootbank_ata-pata-pdc2027x_1.0-3vmw.650.0.0.4564106, VMW_bootbank_ata-pata-serverworks_0.4.3-3vmw.650.0.0.4564106, VMW_bootbank_ata-pata-sil680_0.4.8-3vmw.650.0.0.4564106, VMW_bootbank_ata-pata-via_0.3.3-2vmw.650.0.0.4564106, VMW_bootbank_block-cciss_3.6.14-10vmw.650.0.0.4564106, VMW_bootbank_char-random_1.0-3vmw.650.0.0.4564106, VMW_bootbank_ehci-ehci-hcd_1.0-4vmw.650.0.14.5146846, VMW_bootbank_elxnet_11.1.91.0-1vmw.650.0.0.4564106, VMW_bootbank_hid-hid_1.0-3vmw.650.0.0.4564106, VMW_bootbank_i40en_1.3.1-5vmw.650.1.26.5969303, VMW_bootbank_ima-qla4xxx_2.02.18-1vmw.650.0.0.4564106, VMW_bootbank_ipmi-ipmi-devintf_39.1-4vmw.650.0.0.4564106, VMW_bootbank_ipmi-ipmi-msghandler_39.1-4vmw.650.0.0.4564106, VMW_bootbank_ipmi-ipmi-si-drv_39.1-4vmw.650.0.0.4564106, VMW_bootbank_ixgben_1.4.1-2vmw.650.1.26.5969303, VMW_bootbank_lpfc_11.1.0.6-1vmw.650.0.0.4564106, VMW_bootbank_lsi-mr3_6.910.18.00-1vmw.650.0.0.4564106, VMW_bootbank_lsi-msgpt2_20.00.01.00-3vmw.650.0.0.4564106, VMW_bootbank_lsi-msgpt3_12.00.02.00-11vmw.650.0.0.4564106, VMW_bootbank_misc-cnic-register_1.78.75.v60.7-1vmw.650.0.0.4564106, VMW_bootbank_mtip32xx-native_3.9.5-1vmw.650.0.0.4564106, VMW_bootbank_ne1000_0.8.0-16vmw.650.1.26.5969303, VMW_bootbank_nenic_1.0.0.2-1vmw.650.0.0.4564106, VMW_bootbank_net-bnx2_2.2.4f.v60.10-2vmw.650.0.0.4564106, VMW_bootbank_net-bnx2x_1.78.80.v60.12-1vmw.650.0.0.4564106, VMW_bootbank_net-cdc-ether_1.0-3vmw.650.0.0.4564106, VMW_bootbank_net-cnic_1.78.76.v60.13-2vmw.650.0.0.4564106, VMW_bootbank_net-e1000_8.0.3.1-5vmw.650.0.0.4564106, VMW_bootbank_net-e1000e_3.2.2.1-2vmw.650.0.0.4564106, VMW_bootbank_net-enic_2.1.2.38-2vmw.650.0.0.4564106, VMW_bootbank_net-fcoe_1.0.29.9.3-7vmw.650.0.0.4564106, VMW_bootbank_net-forcedeth_0.61-2vmw.650.0.0.4564106, VMW_bootbank_net-igb_5.0.5.1.1-5vmw.650.0.0.4564106, VMW_bootbank_net-ixgbe_3.7.13.7.14iov-20vmw.650.0.0.4564106, VMW_bootbank_net-libfcoe-92_1.0.24.9.4-8vmw.650.0.0.4564106, VMW_bootbank_net-mlx4-core_1.9.7.0-1vmw.650.0.0.4564106, VMW_bootbank_net-mlx4-en_1.9.7.0-1vmw.650.0.0.4564106, VMW_bootbank_net-nx-nic_5.0.621-5vmw.650.0.0.4564106, VMW_bootbank_net-tg3_3.131d.v60.4-2vmw.650.0.0.4564106, VMW_bootbank_net-usbnet_1.0-3vmw.650.0.0.4564106, VMW_bootbank_net-vmxnet3_1.1.3.0-3vmw.650.0.0.4564106, VMW_bootbank_nhpsa_2.0.6-3vmw.650.0.0.4564106, VMW_bootbank_nmlx4-core_3.16.0.0-1vmw.650.0.0.4564106, VMW_bootbank_nmlx4-en_3.16.0.0-1vmw.650.0.0.4564106, VMW_bootbank_nmlx4-rdma_3.16.0.0-1vmw.650.0.0.4564106, VMW_bootbank_nmlx5-core_4.16.0.0-1vmw.650.0.0.4564106, VMW_bootbank_ohci-usb-ohci_1.0-3vmw.650.0.0.4564106, VMW_bootbank_pvscsi_0.1-1vmw.650.1.26.5969303, VMW_bootbank_qedentv_2.0.3.29-1vmw.650.0.0.4564106, VMW_bootbank_qfle3_1.0.2.7-1vmw.650.0.0.4564106, VMW_bootbank_qflge_1.1.0.3-1vmw.650.0.0.4564106, VMW_bootbank_qlnativefc_2.1.50.0-1vmw.650.1.26.5969303, VMW_bootbank_sata-ahci_3.0-26vmw.650.1.26.5969303, VMW_bootbank_sata-ata-piix_2.12-10vmw.650.0.0.4564106, VMW_bootbank_sata-sata-nv_3.5-4vmw.650.0.0.4564106, VMW_bootbank_sata-sata-promise_2.12-3vmw.650.0.0.4564106, VMW_bootbank_sata-sata-sil24_1.1-1vmw.650.0.0.4564106, VMW_bootbank_sata-sata-sil_2.3-4vmw.650.0.0.4564106, VMW_bootbank_sata-sata-svw_2.3-3vmw.650.0.0.4564106, VMW_bootbank_scsi-aacraid_1.1.5.1-9vmw.650.0.0.4564106, VMW_bootbank_scsi-adp94xx_1.0.8.12-6vmw.650.0.0.4564106, VMW_bootbank_scsi-aic79xx_3.1-5vmw.650.0.0.4564106, VMW_bootbank_scsi-bnx2fc_1.78.78.v60.8-1vmw.650.0.0.4564106, VMW_bootbank_scsi-bnx2i_2.78.76.v60.8-1vmw.650.0.0.4564106, VMW_bootbank_scsi-fnic_1.5.0.45-3vmw.650.0.0.4564106, VMW_bootbank_scsi-hpsa_6.0.0.84-1vmw.650.0.0.4564106, VMW_bootbank_scsi-ips_7.12.05-4vmw.650.0.0.4564106, VMW_bootbank_scsi-iscsi-linux-92_1.0.0.2-3vmw.650.0.0.4564106, VMW_bootbank_scsi-libfc-92_1.0.40.9.3-5vmw.650.0.0.4564106, VMW_bootbank_scsi-megaraid-mbox_2.20.5.1-6vmw.650.0.0.4564106, VMW_bootbank_scsi-megaraid-sas_6.603.55.00-2vmw.650.0.0.4564106, VMW_bootbank_scsi-megaraid2_2.00.4-9vmw.650.0.0.4564106, VMW_bootbank_scsi-mpt2sas_19.00.00.00-1vmw.650.0.0.4564106, VMW_bootbank_scsi-mptsas_4.23.01.00-10vmw.650.0.0.4564106, VMW_bootbank_scsi-mptspi_4.23.01.00-10vmw.650.0.0.4564106, VMW_bootbank_scsi-qla4xxx_5.01.03.2-7vmw.650.0.0.4564106, VMW_bootbank_shim-iscsi-linux-9-2-1-0_6.5.0-0.0.4564106, VMW_bootbank_shim-iscsi-linux-9-2-2-0_6.5.0-0.0.4564106, VMW_bootbank_shim-libata-9-2-1-0_6.5.0-0.0.4564106, VMW_bootbank_shim-libata-9-2-2-0_6.5.0-0.0.4564106, VMW_bootbank_shim-libfc-9-2-1-0_6.5.0-0.0.4564106, VMW_bootbank_shim-libfc-9-2-2-0_6.5.0-0.0.4564106, VMW_bootbank_shim-libfcoe-9-2-1-0_6.5.0-0.0.4564106, VMW_bootbank_shim-libfcoe-9-2-2-0_6.5.0-0.0.4564106, VMW_bootbank_shim-vmklinux-9-2-1-0_6.5.0-0.0.4564106, VMW_bootbank_shim-vmklinux-9-2-2-0_6.5.0-0.0.4564106, VMW_bootbank_shim-vmklinux-9-2-3-0_6.5.0-0.0.4564106, VMW_bootbank_uhci-usb-uhci_1.0-3vmw.650.0.0.4564106, VMW_bootbank_usb-storage-usb-storage_1.0-3vmw.650.0.0.4564106, VMW_bootbank_usbcore-usb_1.0-3vmw.650.1.26.5969303, VMW_bootbank_vmkplexer-vmkplexer_6.5.0-0.0.4564106, VMW_bootbank_vmw-ahci_1.0.0-39vmw.650.1.26.5969303, VMW_bootbank_xhci-xhci_1.0-3vmw.650.0.0.4564106, VMware_bootbank_cpu-microcode_6.5.0-0.0.4564106, VMware_bootbank_emulex-esx-elxnetcli_11.1.28.0-0.0.4564106, VMware_bootbank_esx-xserver_6.5.0-0.23.5969300, VMware_bootbank_lsu-hp-hpsa-plugin_2.0.0-5vmw.650.1.26.5969303, VMware_bootbank_lsu-lsi-lsi-mr3-plugin_1.0.0-10vmw.650.1.26.5969303, VMware_bootbank_lsu-lsi-lsi-msgpt3-plugin_1.0.0-7vmw.650.1.26.5969303, VMware_bootbank_lsu-lsi-megaraid-sas-plugin_1.0.0-8vmw.650.1.26.5969303, VMware_bootbank_lsu-lsi-mpt2sas-plugin_2.0.0-6vmw.650.1.26.5969303, VMware_bootbank_native-misc-drivers_6.5.0-0.0.4564106, VMware_bootbank_rste_2.0.2.0088-4vmw.650.0.0.4564106, VMware_bootbank_vmware-esx-esxcli-nvme-plugin_1.2.0.10-1.26.5969303

Ahora solamente nos queda hacer un reboot:

reboot

Problemas conocidos

Ya os conté el otro día que si recibimos un error del tipo 28 diciendo no space left, podemos solucionarlo de la siguiente manera:

  • https://www.jorgedelacruz.es/2017/12/28/vmware-error-al-actualizar-usando-online-u-offline-depot-errno-28-no-space-left-device/

Extra: aplicar driver de Xeon D with 10GbE

Como recordaréis en mi caso tengo el Homelab perfecto gracias a Supermicro 5028d-tn4t al aplicar updates es seguro que tengamos que instalar de nuevo el VIB con los Drivers de 10GbE, es tan sencillo como lanzar el siguiente comando:

esxcli software vib install -v https://cdn.tinkertry.com/files/net-ixgbe_4.5.3-1OEM.600.0.0.2494585.vib --no-sig-check

Que nos devolverá algo similar a lo siguiente pasados unos minutos:

Installation Result
   Message: The update completed successfully, but the system needs to be rebooted for the changes to be effective.
   Reboot Required: true
   VIBs Installed: INT_bootbank_net-ixgbe_4.5.3-1OEM.600.0.0.2494585
   VIBs Removed: VMW_bootbank_net-ixgbe_3.7.13.7.14iov-20vmw.650.0.0.4564106
   VIBs Skipped:

Un reboot es necesario también:

reboot

Y por supuesto ya podremos ver las interfaces de Red en nuestro Host Client o vSphere Client HTML5:

Enlaces interesantes

Os recomiendo leer los documentos oficiales sobre la Release:

  • https://kb.vmware.com/s/article/2151102?src=vmw_so_vex_akjaer_1025
  • Para más información sobre el perfil de imagen ESXi-6.5.0-20171204001-standard leer el siguiente KB 2151112.
  • Para más información sobre el perfil de imagen ESXi-6.5.0-20171204001-no-tools leer el siguiente KB 2151113.
  • Para más información sobre el perfil de imagen ESXi-6.5.0-20171201001s-standard leer el siguiente KB 2151100.
  • Para más información sobre el perfil de imagen ESXi-6.5.0-20171201001s-no-tools leer el siguiente KB 2151101.

Filed Under: vmware Tagged With: esxi 7273056, esxi 7388607, esxi online depot, ESXi650-201712001, vmware 7273056, vmware 7388607, vmware ESXi650-201712001

Reader Interactions

Comments

  1. Rene says

    4 January, 2018 at 13:53

    Hola,
    Tengo un HP G8 como el tuyo pero con un driver para la controladora B120i “especial” (versión anterior) para evitar el bajo rendimiento de los discos. Si aplico este o cualquier actualización de sistema, este parche sera actualizado también? En caso de que así sea, como lo evito?
    Saludos

    Reply

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

This site uses Akismet to reduce spam. Learn how your comment data is processed.

Primary Sidebar

  • Email
  • GitHub
  • LinkedIn
  • RSS
  • Twitter
  • YouTube

Gold Partners

Silver Partners

Libros Gratuitos

Cloud por vExperts
VMware por vExperts

VMware vExpert

Puesto 16 en Top vBlog

Calendario de Posts

December 2017
M T W T F S S
 123
45678910
11121314151617
18192021222324
25262728293031
« Nov   Jan »

Disclaimer

Todas las opiniones expresadas en este sitio son las mías propias y no representan las opiniones de ninguna compañía con la que haya trabajado, esté trabajando o vaya a estar trabajando.

Copyright © 2026 · El Blog de Jorge de la Cruz